      Fan locations based on Fan status shown in System Summary in the Lenovo BIOS Setup Utility - ThinkCentre M90z

      A post fan error 0135 occurs during POST but the user is unsure which of the three fan locations the error code references.

      Affected configurations

      The above symptom may occur on the following systems:

      • ThinkCentre M90z

      Additional Information or Cause:

      Additional Information or Cause


      To identify which FAN is failing, enter BIOS Setup Utility > System Summary, then check Fan 1/Fan 2/Fan 3 status (Operating, Not Operating). In case "Fan 3 Not Operating," physical location is in the Power Supply Unit.

      See the picture below for fan designations, CPU Fan, System Fan, and Power Supply Fan. Refer to the System service parts listing or HMM for correct FRU number and FRU replacement information.

      Fan designations

      Please click here to see System service parts for ThinkCentre M90z

      Please click here to see Hardware Maintenance Manual (HMM) for ThinkCentre M90z