Symptom

The LSI 9260 RAID card cannot be detected normally when installing an add-on VGA card and installing a LSI 9260 RAID card on Slot 2 using BIOS 3.20.

Affected configurations

The above symptom is associated with, but not limited to, the following systems:

  • ThinkServer TS430 (Type 0387, 0388, 0389, 0390, 0391, 0392, 0393, 0441)

The system is configured with:

  • BIOS is 3.20
  • Add-on VGA card
  • LSI 9260 RAID card installed on Slot 2

Applies To:

  • All Operating Systems

Additional Information:

The LSI 9260 RAID card can be detected normally if an add-on VGA is not installed.  The LSI 9260 RAID card can be detected normally if it is installed on another PCIE slot instead of Slot 2.  The BIOS higher than 3.20 does not have this issue.

Solution

The user can update the BIOS to 3.50, or later, to resolve this issue.