Numeric error codes - ThinkPad R30, R31
Error codeMessageMeaningField replacement unit or action, in sequence
010Memory Error at mmmm: nnnnExtended memory not working or not configured properly at offset nnnn,Change memory module.
041Floppy drive A errorDrive A: or B: is present but fails the BIOS POST diskette tests.Check Floppy drive is attached correctly. Enter Setup to check the type of floppy drive is correct (1.44MB 3.5 inch, for example).
043Floppy drive B error
0175Bad CRC1, stop POST taskEEPROM CRC1 is not correct (block #6).Replace planar.
0188Invalid RFID Serialization Information Area or Bad CRC2EEPROM checksum is not correct (block #0,1).EEPROM CRC2 is not correct (block #6).Replace planar. Box serial number needs to be reinstalled
0189Invalid RFID Configuration Information AreaEEPROM checksum is not correct (block #4,5).Replace planar. UUID needs to be reinstalled.
0193RF antenna had been removedRFID antenna has been removed, which was once installed.RFID model only.
0194The computer is carried through the security gateThe computer is carried through the security gate (portal gate).RFID model only.
0197Invalid remote change requestedThe remote configuration for the security chip has failed.Confirm the operation and try again. The system will go into BIOS Setup automatically.
0200Failure Fixed Disk
Fixed disk is not working or not configured properly.Check to see if fixed disk is attached properly. Run setup. Find out if the fixed disk type is correctly identified.
0210Stuck keyStuck key on keyboard.N/A
0211Keyboard errorKeyboard not working.N/A
0212Keyboard Controller FailedKeyboard Controller Failed test.May require replacing keyboard controller.
0213Keyboard locked Unlock key switch Unlock the system to proceed.
0220Monitor type does not match CMOS Run SETUPMonitor type not correctly identified in Setup.N/A
0230Shadow RAM failed at offset : nnnnShadow RAM failed at offset nnnn of the 64k block at which the error was detected.N/A
0231System RAM failed at offset : nnnnSystem RAM failed at offset nnnn of in the 64k block at which the error was detected.N/A
0232Extended RAM Failed at offset : nnnnExtended memory not working or not configured properly at offset nnnnN/A
0250System battery is dead Replace and run SETUP
The CMOS clock battery indicator shows the battery is dead.Replace the battery and run Setup to reconfigure the system.
0251System CMOS checksum bad-default configurationSystem CMOS has been corrupted or modified incorrectly, perhaps by an application program that changes data stored in CMOS. The BIOS installed Default Setup Values. If you do not want these values, enter Setup and enter your own values. If the error persists, check the system battery or contact your dealer.Enter Setup to configure the system. If the error persists, check the system battery.
0260System timer errorThe timer test failed.Requires repair of system board.
0270Real time clock error.Real time clock fails BIOS hardware test. May require board repair.The mainboard may need the system date and time.
0271Check date and time settingsBIOS found date or time out of range and reset the Real-time Clock. May require setting legal date (1991-2099).Enter Setup to reconfigure the system date and time.
0280Previous boot incomplete - Default configuration usedPrevious POST did not complete successfully. POST loads default values and offers to run Setup. If the failure was caused by incorrect values and they are not corrected, the next boot will likely fail. On system with control of wait states, improper Setup settings can also terminate POST and cause this error on the next boot. Run Setup and verify that wait-state configuration is correct. This error is cleared the next time the system is booted.Ccustomized not to display this message.
0281Memory Size found by POST differed from CMOSMemory size found by POST differed from CMOS.N/A
02B0Diskette drive A error Diskette drive B errorDrive A: or B: is present but fails the BIOS POST diskette tests.Check to see that the drive is defined with the proper diskette type in Setup and that the diskette drive is attached correctly.
02B2Incorrect Drive A type, run SETUPType of floppy drive A: not correctly identified in SetupN/A
02B3Incorrect Drive B type, run SETUPType of floppy drive B: not correctly identified in SetupN/A
02D0System cache error- Cache disabledRAM cache failed and BIOS disabled the cache.On older boards, check the cache jumpers. You may have to replace that cache. See your dealer. A disabled cache slows system performance considerably.
02F0CPU ID:CPU socket number for Multiprocessor error.N/A
02F4EISA CMOS not writeableServerBIOS2 test error: Cannot write to EISA CMOS.N/A
02F5DMA Test FailedServerBIOS2 test error: Cannot write to extended DMA (Direct Memory Access) registers.N/A
02F6Software NMI FailedServerBIOS2 test error: Cannot generate software NMI (Non-Maskable Interrupt).N/A
02F7Fail-Safe Timer NMI FailedServerBIOS2 test error: Fail-safe Timer takes too long.N/A
N/Adevice Address ConflictAddress conflict for specified device.N/A
N/AAllocation Error for: deviceRun ISA or EISA configuration Utility to resolve resource conflict for the specified device.N/A
N/ACD ROM DriveCD ROM Drive identified.N/A
N/AEntering SETUPStarting Setup programN/A


If you are unable to find what you are looking for, please do try the following options:
1. Lenovo Assisted Search
2. Product usage and general troubleshooting tips
3. Lenovo Support Forum
4. Technical Support Call Centre

Country Availability
AvailableWorldwide
Document ID : HT035487
Legacy Document ID : MIGR-39673
Last Updated :
Copyright © Lenovo 2013, all rights reserved
Was this page helpful to you?YesNo


   
Select Task
 
Drivers & Software  
Guides & Manuals  
Diagnose & Fix  
Warranty & Services  
Parts  
Accessories  

ADDITIONAL RESOURCES
Driver Matrix
COMMUNITY
KnowledgeBase Featured Articles
Community KnowledgeBase
Community Forums
Lenovo EMC
Windows 8 Support