Firmware update for Seagate Barracuda ATA IV hard disk drives - PZ1T19A - NetVista
NameOperating SystemVersionReleasedAdd to
download list
Download
now
Installation instructions for firmware update for Seagate Barracuda ATA IV hard disk drives
pz1t19a.txt
3.8 KB
2.0 06 Jan 2004
Firmware update for Seagate Barracuda ATA IV hard disk drives
pz1t19a.exe
989.49 KB
2.0 06 Jan 2004
This package will create a bootable diskette that will update the firmware of a Seagate Barracuda ATA IV hard disk drive from level 3.10 to 8.12, from level 3.19 to 8.19, or from level 3.75 to 8.75.

Do not power off or restart your system while the firmware of your hard disk drive is being updated. Doing so will cause permanent damage to your hard disk drive.

In addition, make sure you back up the data in your hard disk drive before you start updating the firmware.

Print this file so that you can refer to it during the installation.
Additional information

Affected configurations
This update applies only to Seagate hard disk drives that have the following information:

FRU
IBM part number
Model
Capacity (GB)
RPM
19K1565
24P3695
ST320011A
20.4
7200
19K1567
24P3696
ST330011A
30.0
7200
19K1568
24P3697
ST340016A
40.0
7200
19K1570
24P3698
ST360021A
60.0
7200
24P3665
24P3699
ST380021A
80.0
7200

These IDE hard disk drives might come installed in one of the IBM Machine types listed below:

2251, 2259, 2271, 2273, 2289, 6029, 6043, 6049, 6058, 6059, 6568, 6578, 6579, 6599, 6647, 6650, 6790, 6791, 6792, 6793, 6794, 6795, 6822, 6824, 6826, 6830, 6831, 6833, 6840, 6841, 8301, 8303, 8304, 8305, 8306, 8307, 8308, 8309, 8310, 8311, 8312, 8313, 8314, 8315, 8317, 8318, 8319

There are two means by which you can determine if your system has an Seagate ATA IV hard disk drive:

It should be noted that IBM highly recommends using the IBM Enhanced Diagnostics options to determine the vital information relating to the installed hard disk drive. The second option of physically removing the hard disk drive should only be undertaken by technically experienced individuals.

Using IBM Enhanced Diagnostics
IBM Enhanced Diagnostics provides manufacturer, model, and firmware information relating to the installed hard disk drive. This information is shown in the table provided in the affected configurations section. Launch the IBM Enhanced Diagnostics, select Hardware Info, then select IDE Drive Info to locate the Drive Model information. If IBM Enhanced Diagnostics (PC Doctor diagnostics) has been shipped with the system, it may be found in the preloaded IBM software, the F11 Disk-to-Disk recovery partition, the Product Recovery CD, or the IBM Diagnostics CD. The diagnostics are also available for download from the IBM PC support Web site. Click here to download IBM Enhanced Diagnostics.

Physically checking the hard disk drive part numbers
Physically remove the drive from the system. Click here for hardware installation and removal instructions. Make certain that you follow all safety instructions. Locate the IBM part number and FRU part number printed on the drive label, then refer to the table provided in the affected configurations section. Both the IBM part number and the IBM replacement (FRU) part number must match those in the table. If it is determined that the system contains one of the hard disk drives listed in the table above, then update the firmware to the latest release. To verify the current firmware revision of the hard disk drive launch the IBM Enhanced Diagnostics, click Hardware Info, then click IDE Drive Info to view the "Firmware Revision" information.

Downloading the update

  1. Click the file link to download the file from the Web page.
  2. When prompted, select a drive and directory in which to save the downloaded file, be sure to select a path that does not have a space in it's name.

Extracting the update
Installing this update involves creating a bootable diskette. Before you begin, have a blank 1.44 MB diskette ready.

  1. Click Start, select Find or Search, then click Files and Folders.
  2. Insert a blank 1.44MB floppy diskette into the diskette drive.
  3. Type pz1t19a.exe in the search field, then click Find Now. This will locate the pz1t19a.exe file you just downloaded.
  4. Double-click the pz1t19a.exe icon.
  5. Follow the onscreen prompts. The necessary files will be extracted to the diskette.

Installing the update

  1. Close all open applications.
  2. Leave the diskette in the A: drive, and shut down and restart the computer to start the firmware update program.
  3. Follow the onscreen instructions to complete the update process.
  4. If the system has a Seagate Barracuda ATA IV drive that requires the firmware update, the code will be updated automatically.
  5. After the update is complete, remove the diskette and reboot the system for normal operation.
  6. If the hard disk drive does not require the update, then no update will be applied.


If you are unable to find what you are looking for, please do try the following options:
1. Lenovo Assisted Search
2. Product usage and general troubleshooting tips
3. Lenovo Support Forum
4. Technical Support Call Centre

Country Availability
AvailableWorldwide
Document ID : DS001397
Legacy Document ID : MIGR-46086
Last Updated :
Copyright © Lenovo 2013, all rights reserved
Was this page helpful to you?YesNo


   
Select Task
 
Drivers & Software  
Guides & Manuals  
Diagnose & Fix  
Warranty & Services  
Parts  
Accessories  

ADDITIONAL RESOURCES
Driver Matrix
COMMUNITY
KnowledgeBase Featured Articles
Community KnowledgeBase
Community Forums