AMT remote power on/off may not work with ME Power Package 1, 2, or 4 - ThinkCentre M57p, M58, M58p
Symptom

With Intel Management Engine (ME) Power Policy set to Power Package 1, 2, or 4, AMT function "Remote power on/off" may not work.

Affected configurations

The above symptom may occur on the following systems:

  • ThinkCentre M57p (type 9011, 9014, 9071, 9089, 9162, 9303, 6064, 6067, 6073, 6078, 6088, 9196, 9012, 9018, 9087, 9096, 9163, 9193, 9013, 9019, 9088, 9160, 9164, 9194)
  • ThinkCentre M58 (type (6139, 6175, 8820, 7187, 7348, 7359, 7626, 7637, 8910, 7174, 7354, 7360, 7627, 7638, 6258, 6303, 9960, 7244, 7355, 7373, 7628, 7639, 6239, 6302)
  • ThinkCentre M58p (type 7345, 7346, 7347, 7356, 7357, 7358, 7479, 7483, 7484, 7629, 7630, 7635, 8338, 9961, 9964, 9965, 6209, 6137, 7220, 6234, 6138, 7188)

The system Intel Management Engine (ME) supports the following:

Power Package 1 Supported (Desktop: ON in S0)

Power Package 2 Supported (Desktop: ON in S0, S3)

Power Package 3 Supported (Desktop: ON in S0, S3, S4-5)

Power Package 4 Supported (Desktop: ON in S0, ME WoL in S3)

Power Package 5 Supported (Desktop: ON in S0, ME WoL in S3, S4-5)

Power Package 6 Supported (Desktop: ON in S0, S3, S4-5, OFF After Power Loss)

Power Package 7 Supported (Desktop: ON in S0, ME WoL in S3, S4-5, OFF After Power Loss)

With ME Power Policy set to Power Package 1, 2, or 4, ME will be set to an inactive status when the system is in S5 (OFF) modes, so the ME can not react to an AMT power on message and the remote power on will fail.

Solution

Do not replace any hardware.

Change the ME Power Policy setting to Power Package 3 or 5 to correct this issue.

There are several ways to change it:

- Through the MEBx (Management Engine BIOS Extensions)

- Through the WebUI (Web User Interface)

- Through a provisioning server

For more information, please see the vPro White Paper for ThinkCentre M58p at the following URL:

http://www.lenovo.com/support/site.wss/document.do?sitestyle=lenovo&lndocid=MIGR-70799



If you are unable to find what you are looking for, please do try the following options:
1. Lenovo Assisted Search
2. Product usage and general troubleshooting tips
3. Lenovo Support Forum
4. Technical Support Call Centre

Country Availability
AvailableWorldwide
Document ID : HT003523
Legacy Document ID : SF09-D0012
Last Updated :
Copyright © Lenovo 2013, all rights reserved
Was this page helpful to you?YesNo


   
Select Task
 
Drivers & Software  
Guides & Manuals  
Diagnose & Fix  
Warranty & Services  
Parts  
Accessories  

ADDITIONAL RESOURCES
Support Help Index
Technical Specifications - PSREF
Driver Matrix
Newly Released Drivers (RSS)
Community
KnowledgeBase Featured Articles
Community KnowledgeBase
Community Forums
Lenovo EMC
Windows 8 Support

Premium-Support